Description: Quantity: 1 piece
Coil rated voltage (V): AC100
Applicable motor capacity (200闂?40V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.2
Applicable motor capacity (380闂?40V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.7
Applicable motor capacity (500闂?50V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.7
Applicable motor capacity (200闂?20V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.2
Part number: MSO-T10 0.1KW 200V AC100V
Motor capacity (kW): 0.1
Auxiliary contact: 1a
Frame: T10
Compatible thermal relay: With 2-element thermal relay, (Model name): TH-T18
Heater call (A): 0.7
Heat element rated setting range (A): 0.55闂?.85
Coil rated voltage (V): AC100
Type: Open type
Category: Electromagnetic Contactor
Operating method: Non-reversible
Main circuit voltage (V) 200
Specification: Terminal part specification: Standard specification, Operating coil input: Continuous/7VA, Instantaneous input/45VA
Length (mm): 115
Width (mm): 46
Thickness (mm): 79
Mass (kg): 0.36
Mounting method: IEC 35mm rail, screw
Type: AC Operated Type
Frequency (Hz): 50/60
Series: MSO-T
Rated insulation voltage (V): 690
Rated usage current (A): Three-phase squirrel cage motor (AC-3 grade): (200闂?20V) 11/(380闂?40V) 7/(500闂?50V) 6, Resistive load (AC-1 grade) (200闂?40V) 20/(380闂?40V) 11
Mechanical durability: 10 million times
Electrical durability: AC-3 grade: 2 million times, AC-4 grade: 30,000 times, AC-1 grade: 500,000 times
Rated impulse withstand voltage (kV): 6
Pollution degree (operating environment): 3
Switching frequency (times/hour): AC-3 grade: 1800, AC-4 grade: 300, AC-1 grade: 1200
Open thermal current (A): 20
Operating method: Operating coil, Operating circuit: Standard specification
Applicable motor capacity (200闂?40V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.2
Applicable motor capacity (380闂?40V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.7
Applicable motor capacity (500闂?50V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.7
Applicable motor capacity (200闂?20V) (kW): Three-phase squirrel cage motor (AC-3 grade): 2.2
The miniaturization of Electromagnetic Contactors has been achieved for many ratings.
By standardizing the terminal cover, the burden of specifying different model names and arranging options for customers is reduced, leading to inventory reduction and cost-saving effects from the cover. Of course, safety is also improved as protection for the charging parts.
In the old series, the number of operating coil ratings was reduced from 14 to 8, expanding the applicable voltage range. This not only reduces customer inventory but also realizes shorter delivery times through the consolidation of coil manufacturing types.
Suitable for motor overload and binding protection.