Description: Quantity: 1 piece
Coil rated voltage (V): AC200
Applicable motor capacity (200-240V) (kW): Three-phase squirrel cage motor (AC-3 class): 11
Applicable motor capacity (380-440V) (kW): Three-phase squirrel cage motor (AC-3 class): 22
Applicable motor capacity (500-550V) (kW): Three-phase squirrel cage motor (AC-3 class): 22
Applicable motor capacity (200-220V) (kW): Three-phase squirrel cage motor (AC-3 class): 11
Part number: MSO-T50 11KW 200V AC200V
Motor capacity (kW): 11
Auxiliary contacts: 2a2b
Frame: T50
Compatible thermal relay: With 2-element thermal relay, (Model): TH-T50
Heater rating (A): 42
Heat element rated setting range (A): 34-50
Coil rated voltage (V): AC200
Type: Open type
Category: Electromagnetic Contactor
Operation method: Non-reversible
Main circuit voltage (V): 200
Specifications: Terminal part specifications: Standard specifications, Operating coil input: Continuous/10VA, Instantaneous input/110VA
Length (mm): 157.5
Width (mm): 75
Thickness (mm): 91
Weight (kg): 0.79
Mounting method: IEC 35mm rail, screw
Type: AC Operated Type
Frequency (Hz): 50/60
Series: MSO-T
Rated insulation voltage (V): 690
Rated operating current (A): Three-phase squirrel cage motor (AC-3 class): (200-220V) 50/(380-440V) 48/(500-550V) 38
Mechanical durability: 10 million times
Electrical durability: AC-3 class: 2 million times, AC-4 class: 30,000 times, AC-1 class: 500,000 times
Rated impulse withstand voltage (kV): 6
Pollution degree (operating environment): 3
Switching frequency (times/hour): AC-3 class: 1200, AC-4 class: 300, AC-1 class: 1200
Open thermal current (A): 80
Operation method: Operating coil, Operating circuit: Standard specifications
Applicable motor capacity (200-240V) (kW): Three-phase squirrel cage motor (AC-3 class): 11
Applicable motor capacity (380-440V) (kW): Three-phase squirrel cage motor (AC-3 class): 22
Applicable motor capacity (500-550V) (kW): Three-phase squirrel cage motor (AC-3 class): 22
Applicable motor capacity (200-220V) (kW): Three-phase squirrel cage motor (AC-3 class): 11
The miniaturization of Electromagnetic Contactors has been achieved for many ratings.
By standardly equipping a terminal cover, the effort of specifying different model names and arranging options for customers is reduced, leading to inventory reduction and cost reduction effects from the cover. Of course, safety is also improved as protection for the charging part.
In the old series, the number of operating coil ratings was reduced from 14 types to 8 types, expanding the applicable voltage range. This not only reduces customer inventory but also achieves shorter delivery times through the consolidation of coil production types.
It is suitable for overload and restraint protection of motors.